Roof Filter Fans
F2E Cabinet Top Ventilation
Interior
The precondition to use the top fan is that the ambient termperature should be lower than the temperature required in the cabinet.
Function
The high-power centrifugal top fan can vent the high heat load by the greatest degree. The centrifugal fan not only can avoid the vortex vented by the general shield magnetic fan, but also can reduce the noise caused by the friction of air. The FK series of Exit Filter can be used in the inlet in order to prevent from entering the humidity and dust.
Design
The centrifugal top fan is larruping. It is handsome and it has the good function and reasonable structure. It also doesn't take up the interior space. It can well satisfy requirement of the present market with its unique design. The centrifugal top fan is larruping. It is handsome and it has the good function and reasonable structure. It also doesn't take up the interior space. It can well satisfy requirement of the present market with its unique design.
Exhauster on the top Type
F2E190-230-DP
F2E220-230-DP
F2E225-230-DP
Voltage Frequency
230V 50/60HZ
230V 50/60HZ
230V 50/60HZ
Air Flow, Ventilation Freely
570/620m3/h
860/900m3/h
1200/1340m3/h
Flux of air equip filter exported Include filtering pad of standard
1×FK6626.300
456/496m3/h
1×FK6626.300
688/540m3/h
1×FK6626.300
960/1072m3/h
Axle flow blower
Capacitance electromotion
Capacitance electromotion
Capacitance electromotion
Rated Current
0.26A/0.34A
0.38A/0.40A
0.60A/0.88A
Power
58/75W
85/90W
135/200W
Noise Level
62/64dBA
73/74dBA
69/71dBA
Temperature Range
'-10℃~55℃
'-10℃~55℃
'-10℃~60℃
The quantity and size of the wind inlet filter can be decided according to the concrete requirement.
Type
A/B
C
D/E
F/G
H/I
J
ΦK
Φ1
Φ2
L
F2E190-230-DP
270
130
267
310
226.8
98.4
195
7.8
15
97
F2E220-230-DP
270
130
267
310
226.8
98.4
195
7.8
15
97
F2E225-230-DP
270
130
267
310
226.8
98.4
195
7.8
15
97