Top brand Construction
Machinery supplier
Guess you like the video
Air-cooled Screw Chiller(-5℃)
2
Feature
Products Features
1. Twin screw compressor brand is employed, with high efficiency, low noise level, less wearing and long operation time.
2.Four stage volume control or 0%-100% automatic regulation.
3.Use PLC microcomputer control from Germany SIEMENS. LCD touch screen, both English and Chinese human-machina intertace.
4.Perfect breakdown protection: high and low pressure protection, air discharge protection, oil level protection, water flow protection, reverse and lack phase protection, chilled water anti-freezing protection, cooling water overheat protection.

Product options
1.Salt water evaporator
2.Stepless energy regulation
3.Whole heat recovery/partial heat recovery
4.Pump control
5.Special power supply
6.Remote communication connector

Product specfication
Refrigerant: R22/R407C
Evaporator max water pressure drop: 1.0Mpa
Evaporator: fouling factor 0.018m2.℃/KW
Power supply: 380V/3P/50Hz
Allowable voltage fluctuate: ±5%
Allowable frequency fluctuate: ±2%
The unit uses high efficiency heat exchanger with advanced, unique shape design and systems. Units can be installed directly on the roof, or other well-ventilated place outdoors, without a separate room, space saving construction. Compact shape, appearance, unit uses “W” type coil design, space utilization, small unit size, in order to adapt to the outdoor weather conditions to ensure that the unit has a good operating results during the life cycle.
Friendy choose to use environmentally R407C, R134A or R410A refrigerant ect.
There may be change of the dimensions without pre notice. For accurate you are welcome to ask us for installing drawing.

Technical parameter

Air cooled screw chiller(single compressor) -5 ℃ technical parameter


VA-

Type

50SX

65SX

90SX

95SX

115SX

130SX

150Sx

160SX

175SX

190SX

Nominal cooling capacity

kw

48.9

66.9

88.1

95.9

116.9

128.4

151.7

160.3

175.4

189.8

104 kcal/h

4.2

5.8

7.6

8.3

10.1

11.1

13.1

13.8

15.1

16.3

Operating control method

Use PLC microcomputer control

Power Supply

380V/3N/50HZ

Startup type

Y-△

Machine power

kw

27.7

36.5

46.7

52.0

64.6

69.4

77.6

81.1

88.2

95.7

Machine operating current

A

47.4

62.5

80.1

89.5

111.7

119.6

133.5

139.4

151.4

164.4

Compressor

Type

Semi-closed 5:6 asymmetric twin-screw compressor

Input power(kw)

25.0

32.9

41.3

45.3

55.1

60.0

67.6

71.1

78.2

85.3

Rated current(A)

42.0

55.3

69.4

76.1

92.6

100.9

113.6

119.5

131.5

143.5

Energy regulation

0-33%-66%-100%

0-25%-50%-75%-100%

Evaporator

Type

High efficiency dry type shell and tube heat exchanger

Flow(L/min)

9.1

12.4

16.3

17.7

21.6

23.8

28.1

29.7

32.4

35.1

Water pressure drop(kPa)

45.3

41.5

54.2

48.3

48.4

43.6

41.1

47.0

47.9

47.6

Interface size

DN50

DN65

DN80

DN100

Condenser

Type

High efficiency fin type heat exchanger

Fan quantity

6

8

8

3

6

6

6

6

6

6

Stand-alone power

0.4

0.4

0.7

2.2

1.6

1.6

1.7

1.7

1.7

1.7

Refrigerant

Type

R22

Refrigerant volume(kg)

10.9

14.8

19.5

21.3

25.9

28.5

33.6

35.6

38.9

42.1

Overall dimensions

Length(mm)

2500

2950

3150

3450

3050

3050

3550

3550

3550

3500

Width(mm)

1400

1400

1500

1200

2000

2000

2200

2200

2200

2200

Height(mm)

1925

2100

2150

2180

1950

2050

2000

2050

2150

2250

Weight

Machine weight(kg)

1900

2000

2400

2700

2600

2650

2800

3000

3100

3350

Operating weight(kG)

2050

2300

2700

3000

2900

3000

3150

3350

3450

3700


VA-

Type

210SX

245SX

260SX

290SX

310SX

325SX

380SX

415SX

440SX

500SX

Nominal cooling capacity

kw

208.8

248.8

262.7

287.8

311.8

323.9

377.4

414.2

442.4

498.7

104 kcal/h

18.0

21.4

22.6

24.8

26.8

27.9

32.5

35.7

38.1

42.9

Operating control method

Use PLC microcomputer control

Power Supply

380V/3N/50HZ

Startup type

Y-△

Machine power

kw

111.3

124.1

134.3

147.9

157.5

161.9

182.3

211.8

222.9

246.6

Machine operating current

A

192.4

213.1

231.5

255.7

271.9

279.2

313.1

366.5

385.1

424.9

Compressor

Type

Semi-closed 5:6 asymmetric twin-screw compressor

Input power(kw)

94.9

110.2

116.4

126.1

135.7

140.1

161.4

179.0

190.1

213.8

Rated current(A)

159.6

185.3

195.7

212.0

228.2

235.5

271.3

301.0

319.6

359.4

Energy regulation

0-25%-50%-75%-100%

Evaporator

Type

High efficiency dry type shell and tube heat exchanger

Flow(L/min)

38.6

46.0

48.6

53.2

57.7

59.9

69.8

76.6

81.8

92.3

Water pressure drop(kPa)

46.0

48.5

40.8

45.0

41.0

45.9

50.3

44.8

46.1

49.0

Interface size

DN100

DN125

DN150

Condenser

Type

High efficiency fin type heat exchanger

Fan quantity

6

8

8

8

8

8

12

12

12

12

Stand-alone power

2.7

1.7

2.2

2.7

2.7

2.7

1.7

2.7

2.7

2.7

Refrigerant

Type

R22

Refrigerant volume(kg)

46.3

55.2

58.3

63.8

69.1

71.8

83.7

91.9

98.1

110.6

Overall dimensions

Length(mm)

3800

4650

4950

5550

5550

5550

6750

6750

7350

7950

Width(mm)

2200

2200

2200

2200

2200

2200

2200

2200

2200

2200

Height(mm)

2300

2250

2300

2250

2350

2350

2350

2450

2450

2450

Weight

Machine weight(kg)

3800

4400

4600

5200

4700

4900

5600

5900

6200

6600

Operating weight(kG)

4100

4700

4900

5600

5050

4250

6000

6300

6600

7000

Air cooled screw chiller(double compressor) -5 ℃ technical parameter


VA-

Type

100DX

130DX

180DX

190DX

230DX

260DX

300DX

320DX

350DX

380DX

Nominal cooling capacity

kw

97.9

133.9

176.2

191.8

233.9

256.8

303.4

320.6

350.7

379.6

104 kcal/h

8.4

11.5

15.2

16.5

20.1

22.1

26.1

27.6

30.2

32.7

Operating control method

Use PLC microcomputer control

Power Supply

380V/3N/50HZ

Startup type

Y-△

Machine power

kw

55.2

72.6

92.6

100.6

126.6

141.8

157.0

162.1

176.3

197.5

Machine operating current

A

108.6

138.0

169.2

184.2

220.8

239.2

267.2

280.4

307.0

333.6

Compressor

Type

Semi-closed 5:6 asymmetric twin-screw compressor

Input power(kw)

50.0

65.8

82.6

90.6

110.2

120.0

135.2

142.2

156.4

170.6

Rated current(A)

84.0

110.6

138.8

152.2

185.2

201.8

227.2

239.0

263.0

287.0

Energy regulation

0-16.5%-33%-100%

0-12.5%-25%-37.5%-100%

Evaporator

Type

High efficiency dry type shell and tube heat exchanger

Flow(L/min)

18.1

24.8

32.6

35.5

43.3

47.5

56.1

59.3

64.9

70.2

Water pressure drop(kPa)

45.3

41.5

54.2

48.3

48.4

43.6

41.1

47.0

47.9

47.6

Interface size

DN80

DN100

DN125

DN150

Condenser

Type

High efficiency fin type heat exchanger

Fan quantity

6

6

6

6

6

8

8

12

12

12

Stand-alone power

0.9

1.1

1.7

1.7

2.7

2.7

2.7

1.7

1.7

2.2

Refrigerant

Type

R22

Refrigerant volume(kg)

21.7

29.7

39.1

42.5

51.9

57.0

67.3

71.1

77.8

84.2

Overall dimensions

Length(mm)

3150

3150

3550

3550

3950

4850

4850

6750

6750

6750

Width(mm)

2000

2100

2200

2200

2200

2000

2200

2010

2150

2200

Height(mm)

1660

1900

1850

2120

2300

2150

2300

2010

2150

2200

Weight

Machine weight(kg)

3800

4000

4800

5400

5200

5300

5600

6000

6200

6700

Operating weight(kG)

4100

4600

5400

6000

5800

6000

6300

6700

6900

7400


VA-

Type

420DX

490DX

520DX

580DX

620DX

650DX

760DX

830DX

880DX

1000DX

Nominal cooling capacity

kw

417.7

497.7

525.5

575.6

623.6

647.8

754.7

828.4

884.8

997.5

104 kcal/h

36.0

42.8

45.2

49.5

53.7

55.8

65.0

71.3

76.2

85.9

Operating control method

Use PLC microcomputer control

Power Supply

380V/3N/50HZ

Startup type

Y-△

Machine power

kw

222.6

253.2

268.6

295.9

315.1

323.9

364.6

423.5

445.7

493.1

Machine operating current

A

369.2

426.2

449.2

485.4

593.4

609.6

685.1

798.4

639.8

927.0

Compressor

Type

Semi-closed 5:6 asymmetric twin-screw compressor

Input power(kw)

189.8

220.4

232.8

252.2

271.4

280.2

322.8

258.0

380.2

427.6

Rated current(A)

319.2

370.6

391.4

424.0

456.4

471.0

542.6

602.0

639.2

718.8

Energy regulation

0-12.5%-25%-37.5%-100%

Evaporator

Type

High efficiency dry type shell and tube heat exchanger

Flow(L/min)

77.3

92.1

97.2

106.5

115.4

119.8

139.6

153.3

163.7

184.5

Water pressure drop(kPa)

46.0

48.5

40.8

45.0

41.0

45.9

50.3

44.8

46.1

49.0

Interface size

DN150

DN200

Condenser

Type

High efficiency fin type heat exchanger

Fan quantity

12

12

16

16

16

16

24

24

24

24

Stand-alone power

2.7

2.7

2.2

2.7

2.7

1.7

2.7

2.7

2.7

2.7

Refrigerant

Type

R22

Refrigerant volume(kg)

92.6

110.4

116.5

127.7

138.3

143.7

167.4

183.7

196.2

221.2

Overall dimensions

Length(mm)

6750

8750

8750

8750

11100

11100

13
500

13500

14700

15900

Width(mm)

2200

2200

2200

2200

2200

2200

2200

2200

2200

2200

Height(mm)

2380

2250

2350

2450

2350

2350

2350

2450

2450

2450

Weight

Machine weight(kg)

7600

8800

9200

10400

9400

9800

11200

11800

12400

13200

Operating weight(kG)

8200

9400

9800

11200

10100

8500

12000

12600

13200

14000

Cooling condition: Chilled water inlet/outlet temperature 0/-5 ℃, ambient dry bulb temperature 35℃
Chilled water outlet temperature-7~5 ℃
Chilled water side should be added by 25% glycol water or 20% calcium chloride as anti-freeze.


Application
Chemical, chemical fiber, plastic, oil, food, pharmaceutical, military, printing, painting, electroplating, electronics and other industries
Service
Pre-sale services

1. Professional and technical consultation and communication.

2. Equipment selection and quotation.

3. Product application solutions recommendations.

4. Engineering solutions.


After-sale services

Warranty: 12 months guarantee for all products.

Within warranty, any problem caused by the defects of the machine itself, we will offer its service until the problem solved.

Over warranty, we will offer maintenance activity by cost only.

FAQ

Q: How to choose air cooled system or water cooled system? Air cooled is better or water cooled is better?

A: In terms of installation simplicity, the air cooled system is more convenient than the water-cooled system and does not need to connect cooling towers. The water cooled system needs to be connected to the cooling tower then it can run. In terms of energy efficiency, the water cooled system has higher energy efficiency than the air cooled system. Specifically, according to your environment and situation, engineers will design an optimization plan for you.


Q: What is the outlet temperature of your chiller?

A: -55 to 15 centigrade.


Q: What’s payment terms?

A: 50% as deposit, 50% before delivery by T/T, Western Union and Paypal is our regular payment terms. D/P, L/C need to have a discussion.


Q: What is the warranty of water chiller?

A: The standard warranty is 12 months.


Q: What is the  delivery time?

A: Usually around 30 days.


TOP
×
Login

Not a member yet? Create an account

I'am a supplier Login
×
Register

Already got an account? Login

Become a supplier Register