Top brand Construction
Machinery supplier
Guess you like the video
Cross Flow Water Cooling Tower
Description
1. The cooling tower working principle is composite flow type cooling way (hybrid cooling tower) with high efficiency water eliminator and low water drift rate

2. Cooling tower media circulates in closed tubes with no impurities entering, ensuring the pureness of the medium

3. It is better to choose the soft water as circulating water in closed tubes , which won’t scale or block pipeline to ensure the cooling tower performance

4. Spraying system to spray the outer wall of the cooler wet completely by spray water, avoiding forming scale at dry points and improving the system efficiency to the highest degree.

5. Occupy a little area and can be moved and laid according to requirement, the maintenance cost of cooling tower in the future is low. Widely used in cooling tower treatment chemicals

6. Composite flow type closed water cooling tower is energy-saving type cooling tower of which the water in the cooling coils can flow back to the water tank to ensure the equipment not be freezen off when the equipment doesn’t operate in lower temperature in some northern areas.

7. Cooling tower controls using the automatic digital vision temperature controller for saving energy and protecting environment in closed cooling system.

Parameters
Model Cooling Capacity Overall Dimension Fan System Spray Pump Pipe mouth Weight
Max. Water Flow Thermal Power L W H Diameter Power Air capacity Power Inlet Outlet Overflow Discharge Make-up Dry Running
m3/h kW mm mm mm mm kw m3/h kw DN mm DN mm DN mm DN mm kg kg
FBF-10D 10 58 1800 1500 2080 Φ700
Φ700
0.55
0.55
6400
6400
0.75 65 25 25 25 640 1730
FBF-15D 15 87 1800 1500 2300 Φ750
Φ750
0.75
0.75
9600
9600
0.75 65 25 25 25 710 1880
FBF-20D 20 116 1800 1500 2550 Φ800
Φ800
0.75
0.75
12800
12800
0.75 80 25 25 25 810 1920
FBF-30D 30 174 2000 1800 2680 Φ800
Φ800
1.5
1.5
19200
19200
0.75 80 25 25 25 920 2320
FBF-40D 40 232 2500 1800 2730 Φ1000
Φ1000
1.5
1.5
25600
25600
1.1 100 32 32 32 1200 2860
FBF-50D 50 290 2500 2000 2930 Φ1000
Φ1000
1.5
1.5
32000
32000
1.5 100 32 32 32 1380 3200
FBF-65D 65 378 2650 2300 2950 Φ1200
Φ1200
2.2
2.2
41600
41600
1.5 100 32 32 32 1620 3980
FBF-80D 80 465 3300 2300 3100 Φ1200
Φ1200
3
3
51200
51200
2.2 125 40 40 40 2280 5330
FBF-100D 100 581 4000 2600 3150 Φ1500
Φ1500
4
4
64000
64000
4 125 40 40 40 2800 7150
FBF-125D 125 727 4500 2700 3200 Φ1500
Φ1500
5.5
5.5
80000
80000
4 150 40 40 40 3290 7780
FBF-150D 150 872 5000 3200 3940 Φ1500
Φ1500
Φ1500
3
3
3
64000
64000
64000
5.5 150 40 40 40 3880 9800