Top brand Construction
Machinery supplier
Guess you like the video
Marine Chiller Unit
Feature
Products Features
1.Evaporator: Dx type evaporator, refrigerant running insde heat excahnger pipes. Water side design pressure 10bar; refrigerant side design pressure 25bar. Evaporator outside packed with 10mm insulation material, prevent heat transfer with outdoor air and reduce energy consumption.
2.Liquid loop control valve: using imported valve, can highly reduce the refrigerant gas loop resistance:meantime when filters is stuck, it is easy to exchange filter core and clean filter boday.
3.Dry type filter: adopt welding tangle-type filter, tis core is imported molecular sieve, can filtrate water, acid and easy to replace.
4.Expansion valve: using imporred expansion valve, its purpose is to adjust refrigeration flow into evaporator according to evaporate temperature, and maintain a certain pressure so as to ensure the evaporating efficiency.
5.High strength structure coated with anti-corrosion paint: whole unit structure is made of high strength steel channel and appearance coated with anti-salt, fog corrosion navy paint. All to ensure the unit to be high strength, excellent vibration control performance and perfectly anti-corrosion and moisture proof.

Application
It is widely used in all kinds of passenger ships, cargo ships, warships and offshore oil platfroms
Technical parameter
Marine air cooled screw chiller unit specification

Model MWAL130 MWAL160 MWAL210 MWAL240 MWAL300 MWAL390 MWAL470 MWAL480D MWAL600D MWAL700D MWAL780D MWAL940D
Rated Cooling Capacity 50HZ KW 130 160 210 240 300 390 470 480 600 700 780 940
60HZ 160 190 250 290 360 470 560 580 720 840 940 1120
Rated Input Power 50HZ KW 46 53 69 80 99 127 140 160 198 226 253 280
60HZ 55 64 83 96 120 153 172 192 240 273 306 343
Chilled Water Indoor and Outdoor Temperature 7-12℃
Compressor Type 6+7semi-hermetic two-screw
Quantity 1 1 1 1 1 1 1 2 2 2 2 2
Refrigerant Name R22/R407c
Max Ambient Temperature 45℃
Throttling devices External equalizer thermostatic expansion valve/Electronic expansion valve
Refrigerant Charge Kg 48 54 62 74 85 115 145 162 162 171 230 290
Air side heat exchanger Corrugated aluminum fins hydrophilic membrane kit thread brass
Condensing Fan Model Ultra low-noise axial fan
Power 50HZ KW 1.1×4 1.5×4 1.5×4 1.5×6 1.5×6 1.5×8 1.5×10 1.5×10 1.5×12 1.5×12 1.5×12 1.5×16
60HZ 1.5×4 1.5×4 1.8×4 1.8×6 1.8×6 1.8×8 1.8×10 1.8×10 1.8×12 1.8×12 1.8×16 1.8×16
Evaporator Model Dry Shell and Tube
Chilled water Flow 50HZ m3/h 23 28 37 42 52 67 82 82 104 120 135 162
60HZ 28 33 43 50 62 82 100 100 124 145 162 193
Diameter 50HZ mm DN80 DN80 DN80 DN100 DN100 DN100 DN125 DN125 DN125 DN150 DN150 DN150
60HZ DN80 DN80 DN100 DN100 DN100 DN125 DN125 DN125 DN150 DN150 DN150 DN200
Water resistance KPa 50-80
Noise dB
(A)
64 64 64 65 65 66 66 67 68 68 69 70
Dimension Length 50HZ m 2200 2300 2400 3000 3500 4500 5000 5000 3500*2 4000*2 4500*2 5000*2
60HZ 2300 2400 3000 3500 4000 5000 7200 3500*2 4000*2 4600*2 5000*2 6000*2
Width m 2250 2300 2300 2300 2300 2300 2300 2300 2300 2300 2300 2300
Height m 2250 2450 2450 2550 2550 2550 2550 2550 2550 2550 2620 2620

Chilled water inlet temperature:12℃,Chilled water outlet temperature: 7℃,air side dry bulb temperature: 35℃,wet bulb temperature: 24℃.
*represent option
Service
Pre-sale services

1. Professional and technical consultation and communication.

2. Equipment selection and quotation.

3. Product application solutions recommendations.

4. Engineering solutions.


After-sale services

Warranty: 12 months guarantee for all products.

Within warranty, any problem caused by the defects of the machine itself, we will offer its service until the problem solved.

Over warranty, we will offer maintenance activity by cost only.

FAQ

Q: How to choose air cooled system or water cooled system? Air cooled is better or water cooled is better?

A: In terms of installation simplicity, the air cooled system is more convenient than the water-cooled system and does not need to connect cooling towers. The water cooled system needs to be connected to the cooling tower then it can run. In terms of energy efficiency, the water cooled system has higher energy efficiency than the air cooled system. Specifically, according to your environment and situation, engineers will design an optimization plan for you.


Q: What is the outlet temperature of your chiller?

A: -55 to 15 centigrade.


Q: What’s payment terms?

A: 50% as deposit, 50% before delivery by T/T, Western Union and Paypal is our regular payment terms. D/P, L/C need to have a discussion.


Q: What is the warranty of water chiller?

A: The standard warranty is 12 months.


Q: What is the  delivery time?

A: Usually around 30 days.


TOP
×
Login

Not a member yet? Create an account

I'am a supplier Login
×
Register

Already got an account? Login

Become a supplier Register