Model |
UNIT |
NLPW- |
|||||||
3.1 |
5.1 |
8.1 |
10.1 |
12.1 |
15.1 |
||||
Btu |
33438 |
54251 |
97583 |
108160 |
123856 |
156952 |
|||
RT |
2.8 |
4.5 |
8.1 |
9.0 |
10.3 |
13.1 |
|||
Kw |
9.8 |
15.9 |
28.6 |
31.7 |
36.3 |
46 |
|||
×10³Kcal/h |
8.4 |
13.7 |
24.6 |
27.3 |
31.2 |
39.6 |
|||
Total Power |
KW |
2.50 |
4.10 |
6.40 |
7.20 |
8.40 |
11.30 |
||
Total Current |
A |
4.40 |
7.20 |
11.50 |
12.70 |
15.00 |
20.10 |
||
Compressor |
Qty |
set |
1.00 |
1.00 |
1.00 |
1.00 |
1.00 |
1.00 |
|
Input power |
KW |
2.10 |
3.50 |
5.70 |
6.40 |
7.30 |
10.20 |
||
Operation Current |
A |
3.70 |
6.20 |
10.10 |
11.40 |
13.00 |
18.10 |
||
Condenser |
Type |
High efficiency copper dry type shell-and-tube heat exchanger |
|||||||
Cooling Water Flow |
L/min |
35 |
57 |
102 |
113 |
130 |
164 |
||
Water Pipe Connection |
mm |
25 |
25 |
32 |
32 |
40 |
40 |
||
Evaporator |
Type |
Horizontal shell-and-tube/Coil type high efficiency copper heat exchanger |
|||||||
Freezing water Flow |
L/min |
28 |
46 |
82 |
91 |
104 |
132 |
||
Water pipe connection |
mm |
25 |
25 |
32 |
32 |
40 |
40 |
||
Freezing Water Pump |
Type |
High efficiency, low noise |
|||||||
Input Power |
Kw |
0.37 |
0.55 |
0.75 |
0.75 |
1.1 |
1.1 |
||
Head |
m |
15 |
20 |
19 |
19 |
17 |
25 |
||
Refrigerant |
Type |
|
|||||||
Water tank Indicating Volume |
Liter |
80 |
90 |
190 |
190 |
190 |
210 |
||
Safety protection |
high and low pressure protection, overload protection, over temperature protection, phase sequence protection, etc. |
||||||||
Dimensions (L*W*H) |
Length |
mm |
1150 |
1150 |
1350 |
1350 |
1350 |
1600 |
|
Width |
mm |
750 |
750 |
850 |
850 |
||||
High |
mm |
900 |
900 |
1200 |
1200 |
1200 |
|||
Total Weight |
KG |
150 |
220 |
310 |
360 |
450 |
650 |
Note:
1.Freezing water inlet temperature 12 ℃, freezing water outlet temperature 7 ℃; cooling water inlet temperature of 30 ℃, cooling water outlet temperature of 35 ℃;
2.Temperature conditions: Freezing water outlet temperature range 5 ℃ -15 ℃, cooling water inlet temperature range 19 ℃ -33 ℃;
3.Safe operating range : Freezing water inlet temperature 9℃-20℃;
4. The using compressor is closed turbine imported from Europe and the United States, superior performance, strong ability of anti-effusion;
5. Nominal operating conditions in the evaporator and condenser water side fouling factor of 0.018m²℃ / kw, condenser water side fouling factor of 0.044 m²℃ / kw;
6. Water side of the evaporator and condenser, designed to withstand a pressure of 1.0MPa;
7. The actual head of Host is that the pump head minus head losses within the host;
8. In addition to the specifications and requirements. We can provide non-standard products according to customer requirements.
1. Professional and technical consultation and communication.
2. Equipment selection and quotation.
3. Product application solutions recommendations.
4. Engineering solutions.
After-sale services
Warranty: 12 months guarantee for all products.
Within warranty, any problem caused by the defects of the machine itself, we will offer its service until the problem solved.
Over warranty, we will offer maintenance activity by cost only.
Q: How to choose air cooled system or water cooled system? Air cooled is better or water cooled is better?
A: In terms of installation simplicity, the air cooled system is more convenient than the water-cooled system and does not need to connect cooling towers. The water cooled system needs to be connected to the cooling tower then it can run. In terms of energy efficiency, the water cooled system has higher energy efficiency than the air cooled system. Specifically, according to your environment and situation, engineers will design an optimization plan for you.
Q: What is the outlet temperature of your chiller?
A: -55 to 15 centigrade.
Q: What’s payment terms?
A: 50% as deposit, 50% before delivery by T/T, Western Union and Paypal is our regular payment terms. D/P, L/C need to have a discussion.
Q: What is the warranty of water chiller?
A: The standard warranty is 12 months.
Q: What is the delivery time?
A: Usually around 30 days.