WHI 4 series
●Comply with the most common standard in terms of GB755, EN ISO 12100, EN 12601, EN 60204-1
●Single or double bearings are available, options for all kinds of adaptors and coupling disc
●12-end reconnectable winding terminals to get different voltages
●Standard “H” insulation class
●Convenient installation and maintenance for rotated diodes and adaptor connected bolts
●Standard sealed maintenance-free bearings
Options
●Air filter
●Droop CT
●PMG excitation system
●Winding RTD and bearing RTD
●IP23 or IP22 Protection
●Anti-condensation heater
●Winding protection thermistor and relay
WATTEK ALTERNATOR
SPECIFICATION
|
|
4 POLES |
4 POLES |
||||||
VOLTAGE |
50Hz 1500rpm |
60Hz 1800rpm |
|||||||
STAR-SERIES |
380 |
400 |
415 |
416 |
440 |
480 |
|||
STAR-PARALLEL |
190 |
200 |
208 |
208 |
220 |
240 |
|||
TRIANGLE-SERIES |
220 |
230 |
240 |
240 |
254 |
277 |
|||
WHI 4C |
RATED CAPACITY (kVA) |
250 |
250 |
250 |
294 |
300 |
300 |
||
|
RATED POWER (kW) |
200 |
200 |
200 |
235 |
240 |
240 |
||
|
EFFICIENCY (%) |
92.5 |
92.4 |
92.7 |
92.4 |
92.6 |
92.6 |
||
|
|
|
|
|
|
|
|
||
WHI 4D |
RATED CAPACITY (kVA) |
294 |
294 |
294 |
350 |
356 |
362 |
||
|
RATED POWER (kW) |
235 |
235 |
235 |
280 |
280 |
290 |
||
|
EFFICIENCY (%) |
92.3 |
92.7 |
93 |
92.6 |
92.7 |
92.8 |
||
|
|
|
|
|
|
|
|
||
WHI 4E |
RATED CAPACITY (kVA) |
312.5 |
312.5 |
312.5 |
375 |
394 |
400 |
||
|
RATED POWER (kW) |
250 |
250 |
250 |
300 |
315 |
325 |
||
|
EFFICIENCY (%) |
93.2 |
93.5 |
93.6 |
93.3 |
93.5 |
93.7 |
||
|
|
|
|
|
|
|
|
||
WHI 4FS |
RATED CAPACITY (kVA) |
344 |
344 |
344 |
415 |
425 |
440 |
||
|
RATED POWER (kW) |
275 |
275 |
275 |
332 |
340 |
352 |
||
|
EFFICIENCY (%) |
93.1 |
93.3 |
93.5 |
93.2 |
93.5 |
93.5 |
||
|
|
|
|
|
|
|
|
||
WHI 4F |
RATED CAPACITY (kVA) |
375 |
375 |
375 |
450 |
450 |
450 |
||
|
RATED POWER (kW) |
300 |
300 |
300 |
360 |
360 |
360 |
||
|
EFFICIENCY (%) |
93.0 |
93.2 |
93.3 |
93.0 |
93.3 |
93.4 |
The alternator has been designed for use in a maximum ambient temperature of 40℃ and altitude less than 1000 meters above sea level. The power factor is 0.8, and the level of raising temperature is H class (125℃)