SHENNY Generator Sets(20kW to 500kW)
Engine Brand : SHENNY
Structure : Open Type
Power : 25KVA-4713KVA
Industry : Real Estate
Special Application : Natural Gas Power Station
Product Details
Generator  sets
Generator model N25 N27.5 N50 N100 N150 N181 N288 N375 N625
Rated power(kW/kVA) 20/25 22/27.5 40/50 80/100 120/150 145/181 230/288 300/375 500/625
Output heatl power(kW/kVA) 15 17 34 64 95 117 171 232 400
Electric efficiency(%) 29.3 27.8 30.7 32.5 30.3 32.5 35.3 33.9 32.6
Fuel LPG NG、LNG
Gas consumption(m³/h) 2.7 8.5 14 26.5 39 48 70 95 165
70℅ gas consumption(m³/h) 2.1 6.5 11 20.5 28.5 37 54 73.5 127.5
50% gas consumption(m³/h) 1.5 5 8 14.5 20 26 38 52 90
Voltage(V) 400/230
Frequency(HZ) 50
Engine
Brand SHENNY
Engine Model P4L2.8G N4L2.8G N4L3.9TAG N6L5.9TWG N6L8.3TWG N6L8.9TWG N6L14TWG N6L19TWG N12V38TWG
Engine characters Vertical, in line,4-cycle
60° V , 4 –cycle,
Aspirated Naturally aspirated Aircooled, turbo turbo & water (air )cooled
Compression ratio 9:1 12:1 11:1 10.5:1
Number of cylinders 4 6 12
Bore×Stroke(mm) 93×102 102×120 114×135 114×145 140×152 159×159 159×159
Displacement(L) 2.77 3.9 5.9 8.3 8.9 14 18.9 37.8
Oil consumption(g/kWhr) 1.4 0.9
Speed(rpm) 1500
Rated power(kW) 24 26 45 90 130 160 250 325 550
Combustion type Equivalence combustion Lean- burn
Excess air factor(Lambda)(λ) 1~1.25 1.25~1.4
Overhaul interval(h) 20000
Alternator
Alternator Model Stamford/Meccalte/Leroy-somer
Rated capacity(kVA) 25 30 50 105 150 200 300 400 625
Rated power(kW) 20 24 40 84 120 160 240 320 500
Efficiency(%) 87.80% 88.10% 88.90% 92.20% 93.20% 92.40% 93.70% 94.20% 95%
Voltage regulation ±0.5%
Power factor 0.8
Overspeed(rpm) 2250
Sustained short circuit 300%(3IN):20S
Protection IP23